AC Input Input rating1 100 to 240 VAC, 50/60 Hz, 15 - 7. Single-channel system source measure unit smu (16 pages) Measuring Instruments National Instruments PXIe-4080 Calibration Procedure. 注意: pxie-414x 和 pxie-4136 / 4137/4138/4139 具有可将电流值设为0a优点,可以不吸收电流;这在测量高阻抗电压源时至关重要。所有其他smu不能将电流值设为0,该电流将被 smu 吸收。下表列出了smu设备的可设置的最小电流值。This adapter is rated for 60 V DC maximum voltage and is not a recommended accessory for the PXIe-4136 or PXIe-4137 due to the 200 V DC output of those SMUs. If you need a specific firmware or series relating to PXIE-1062Q, we probably have it. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40Sample rate accuracy Equal to PXIe_CLK100 accuracy, nominal Maximum measure rate to host 1. The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. com | PXIe-4137 Calibration Procedure. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. •Current Sesitivity: 1 pA. Price may vary with addition of accessories and services. This document explains how to install, configure, and test the NI PXIe-4136/4137 (NI 4136/4137). Sinau babagan fitur utama, kalebu pangukuran kacepetan dhuwur, urutan wektu hardware, lan pulsing jarak sing luwih dawa. 3 GHz) PXIe-6345: PXIe-6355: PXIe-6365: PXIe-6375: PXIe-6614: PXIe-6674T: VB-8012: NI 9222 (BNC) NI 9223 (BNC) NI 9238: Calibration Executive 3. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. National Instruments PXIe-4143 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 4 Voltage Range: -24 V to 24 V Current Range: -150 mA to 150 mA Current Sesitivity: 10 pA Source Adapt: Yes Part Number: 153690A-02L, 782431-01The PXIe-8510 is a hardware-selectable controller area network (CAN) and/or local interconnect network (LIN) interface for developing applications with the NI-XNET driver. Options. 1 1 0. The PXIe-5668 achieves extremely wide instantaneous bandwidth using its 2 GS/s digitizer. PDF. PXIe-4136 measuring instruments pdf manual download. com for more information about these additional items. This module can function as an LVDT, RVDT or Resolver simulator and occupies just one PXI or LXI chassis slot. Rate the PXIe-4136. com. 2-3U PXI Express storage unit provides up to 15. It is a hardware-timed instrument with a high-speed. Standard Package. All prices are shown in USD. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. National Instruments PXIe-1082 PXI Chassis. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Part Number: 783760-01. Screw Terminal Connector Kit, Smu; Accessory Type:Screw Terminal Connector Kit; For Use With:Ni Pxie-4136/7/8/9 Smus; Product Range:- Rohs Compliant: Yes |Ni 784068-01. 2 TB of NVME SSD storage in a single PXI Express slot. Click here to sell your equipment! More Information. Single-channel system source measure unit smu (16 pages) Measuring Instruments National Instruments PXIe-4080 Calibration Procedure. Are you in EU? Call: +44 1782 576800. secure the SA-413B onto a PXIe-4136/4137/4138/4139 using the two retaining screws to a torque of 0. We would like to show you a description here but the site won’t allow us. The NI 6592R provides access to FPGA multi-gigabit transceivers (MGTs) via Component Level IP (CLIP) for use in the following applications: • Functional test for semiconductor production • Protocol functional testBuy 784781-01 - Ni - Chassis, PXIe-1092, PXI System, 9 Slots, 3U. The PXIe-4135 is a high-precision, system source measure unit (SMU). Measuring Instruments NI PXIe-4136 Calibration Manual. The user can utilize Guard terminals to actualize guarding strategies in cabling and test installations. pxie-4136系统源测量单元(smu)具有高功率、高精度和高速度等优点,并采用四象限运行模式。该设备是一款具有高速序列生成引擎的硬件定时仪器,用于同步多个smu之间的采集。该模块支持上位机和smu之间的直接dma数据流,使您能够以仪器的最大更新速率和采样率. Learn more about its features and specifications on this webpage. PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit. All other SMUs will have a non-zero current which will be sinked in the SMU. Guaranteed | (888) 88-SOURCE | applies to the PXIe-4136 (40W) when used with any chassis and only applies to the PXIe-4136 (40W) when used with a chassis with slot cooling capacity <58W. Part Number: 783625-01. Table 2. 5 Replies 6 New. Request a quote and receive a price in about 15 minutes. The excellent dynamic range. com todayPXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. Octopart is the world's source for 784068-01 availability, pricing, and. 6. PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。Find the best pricing for National Instruments 784068-01 by comparing bulk discounts from 3 distributors. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. 12. Ask for a quote on a Used Miscellaneous Test Equipment from Apex Waves, LLC at used-line. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. com | PXIe-4136 Specifications Maximum measure rate to host 1. 1. The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit. •Voltage Range: -60 V to 60 V. •Voltage Range: -200 V to 200 V. M9010A 10-slot PXIe chassis, Gen 3 delivers industry-leading sound power levels combined with exceptional per-slot cooling to meet the demands of high-performance PXIe modules. The NI PXIe-5413 ’s frequency step size is 2. 8 MS/s per channel, continuous, nominal Maximum source update rate 13 100,000 updates/s, nominalThe PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. The module supports DMA streaming between the host PC and SMU, so you can stream. National Instruments PXIe-4145 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 4. This arbitrary waveform generator can generate signals from -12 V to +12 V and uses a fractional. Technical Documents (0) Available to manufacturer lead time 9 weeks. SMU (PXIe 4136) as a DC Current Source Solved! Go to solution. Description. Input rating 100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A Operating voltage range. Part Number: 783762-01. PXIe, -200 V, -1 A (DC)/-3 A (Pulsed), 1 pA / 100 fA Precision System PXI Source Measure Unit. Buy 783760-01 - Ni - Source Measure Unit SMU, 1-Channel, 4-Quadrant, PXIe-4136, ± 1A, ± 200V, 20W. The device is equipped with a four-wide 3U PXI Express module. PXI/PXIe. The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. Home; About us; Products; News. Pxie, 6 1/2-digit, +/-300 v, onboard 1. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. the reported current is very close to the set current (within 0. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Labels: Current; Current Source; PXIe-4136; SMU;The PXIe‑1071 is designed for a wide range of test and measurement applications and provides a high-bandwidth backplane. 8 Weeks. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. element14 Malaysia offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. Datasheet & Specifications. PXIe-4136 Product Certification(s) You can request repair, schedule calibration, or get technical support. PXIe-4136 (783760-01) PXI Express: 1: 20 W: 12 W-200 V to 200 V:PXIe-4162 - Price and Info. These modules can be connected together to create a baseband loopback test system, connected to the PXIe-3620 IF module, or to 3rd party. National Instruments PXIe-4141 Source Measure Unit (SMU) •Number of SMU Channels: 4 •Voltage Range: -10 V to 10 V •Current Range: -100 mA to 100 mA •Current Sesitivity: 10 pA •Source Adapt: Yes Part Number: 150660B-02L. 157420-01L. 通常當發生此錯誤時,不正確的連接包括反轉檢測端子的極性、將檢測引線短接在一起或本地檢測 HI 或 LO 的連接鬆動。. Unit Price. To determine which version of the module you have, locate the device name in one of the following places: • In MAX —The PXIe-4135 (40W) shows NI PXIe-4135 (40W), and the PXIe-4135 (20W) shows as NI PXIe-4135. The NI 4136/4137 is a single-channel system source measure unit (SMU). Attribute. com. Tindakake pandhuan langkah-langkah kanggo instalasi, konfigurasi, lan ngawasi pangukuran. Specifications are subject to. Product Overview. PXIe-4162 configured for normal transient response. Additional information. 90 VAC to 264 VAC Nominal input frequency 50 Hz/60 Hz. The Trifecta A2000 GPU supports 8GB of GDDR6 memory, up to 8. Also for: Pxie-4137. The solution is limited to a maximum output frequency of 5 kHz. The PXIE-8379 (Part Numbers: 782991-01) is a MXI Controller that allows for PXI chassis control from a PC, laptop, desktop, or rackmount control system. 注意: pxie-414x 和 pxie-4136 / 4137/4138/4139 具有可将电流值设为0a优点,可以不吸收电流;这在测量高阻抗电压源时至关重要。所有其他smu不能将电流值设为0,该电流将被 smu 吸收。 Price does not include VAT. The block diagram for the signal calculation is shown by the following picture: I am using a PXIe-4136 and LabVIEW™is detecting a "hazardous voltage" even though I am within the safety limit. It is a test and measurement platform that combines a controller with measurement instruments in a multi-slot chassis. National Instruments PXIe-4136 Datasheet (pdf) National Instruments PXIe-4137 Datasheet (pdf) National Instruments PXIe-4138 Datasheet (pdf)PXIe-4163 - Price and Info. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 2 T cal is the internal device temperature recorded by the PXIe-4112 at the completion of the last external calibration. PXIe-4162 PXIe-4163 Issue Details I would like to simulate battery cells connected in series using SMU-s. The NI 4136/4137 is a single-channel system source measure unit (SMU). There is a safety interlock test procedure in the Getting Started Guide for the PXIe-4136 using the NI-DCPower Soft Front Panel. 這些卡監控 HI 和 HI SENSE 之間的電壓差,如果. e. 884. Ask for a quote on a Used Miscellaneous Test Equipment from Apex Waves, LLC at used-line. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. SMU (PXIe 4136) as a DC Current Source michberk. It is your responsibility to determine the correct and up to date import or export classification. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V. SMU (PXIe 4136) as a DC Current Source michberk. Qty Unit Price Ext Price; 1: $7,725. Banana cables must be unplugged 1 Maximum voltage measured between the HI, HI Sense, LO, LO Sense, or Guard terminals. This model offers either two or six XNET ports that you can use as CAN or LIN ports, depending on the accessory you connect. The PXIE-8379 creates a multichassis PXI system for optimal. 1 Year Warranty. Figure 1. Price may vary with addition of accessories and services. NI PXIe-4162 Source Measure Unit (SMU) Stock # 95045-12 Add to Cart. Buy 784058-01 - Ni - Chassis, PXIe-1084, PXI System, 18 Slots, 3U. This module also has 32 input channels up to 400 kS/s total (up to 4 channels per ADC). PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. The analog voltage is 10 V maximum. NI is now part of Emerson. Products. PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 PXIe-4140. g) Ensure that there is no exposed wiring, cable ground shield, or drain wire in the shaded region: 8. È uno strumento a temporizzazione hardware con un motore di sequencing ad alta velocità per sincronizzare le acquisizione tra più SMU. SMU specifications take precedence if the SMU model is rated for lower voltage. 8 | ni. The PXIe-5413 is a 20 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. Figure 1. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDF UL, Product Safety: View: Product Support Resources. py","path":"src/nidcpower/metadata/__init__. 25 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module. This document contains specifications for the PXIe-1083 chassis. NI PXIe-4309 Flexible Resolution PXI Analog Input Module Stock # 95189-1 Add to Cart. Ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as Resolvers. The PXIe-5644 by National Instruments is In Stock & Ready to Ship at Apex Waves. 2W. PXIe-4136 measuring instruments pdf manual download. Analog-to-digital converter technology and native triaxial connectors help you. Order toll free: 800. ). 這些卡監控 HI 和 HI SENSE 之間的電壓差,如果. 6. The NI PXIe-4136 has Free Ground Shipping. 01 1 0. This applies to the PXIe-4136 (40W) when used with any chassis and only applies to the PXIe-4136 (40W) when used with a chassis with slot cooling capacity <58W. ). The following figure shows the front panel and pinout of the PXIe-6570 digital pattern instrument. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. Contact us with questions for pricing. PXIe-4136製品 の 規格 認証 - NI ホームページに戻るRevisions C and later of the PXIe-4136/7, and revisions H and later of the PXIe-4138/9 now include an additional 4 connection points for chassis ground on the main front panel connector, revealed by 4 extra holes in the front panel sticker overlay. Price may vary with addition of accessories and services. PXIe-4136 Getting Started Guide(s) PXIe-4136 Calibration Procedure(s) Visual Diagrams . The NI PXIe-4136 has Free Ground Shipping and a 1-3 Year Warranty, depending on New, Reconditioned, Used, or Repair Status of the model. 1. 6 (patch) PXIe-4302: TB-4302: PXIe. Email: info@artisantg. NI PXIe-4136 Calibration Manual (26 pages) CALIBRATION PROCEDURE, SINGLE-Channel SYSTEM SOURCE MEASURE UNIT (SMU) Brand: NI. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. CCA,NI PXIE-4136 SYSTEM SMU. 1 1 0. Could you try going through those steps and seeing if that allows you to reset the safety interlock? If going through the safety interlock test in step 5 above fails, your PXIe-4136 SMU may be damaged. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. This module features analog-to-digital. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Price may vary with addition of accessories and services. Electrical The following section provides information about the PXIe-1095 AC input and DC output. Member 08-29-2023 09:25 AM. 3 N · m (2. Measure the internal device temperature and perform self-calibration if necessary. This document explains how to install, configure, and test the NI PXIe-4136/4137 (NI 4136/4137). All specifications are subject to change without notice. Fast Shipping. Buy 784068-01 - Ni - Screw Terminal Connector Kit, PXIe-4136/7/8/9 SMUs. 6 GHz and up to 765 MHz of instantaneous bandwidth at center frequencies from 3. PathWave Connectivity Lab. PXIe-2529 User Manual(s) PXIe-2529 Getting Started Guide(s) Visual Diagrams . Price may vary with addition of accessories and services. Measure the internal device temperature and perform self-calibration if necessary. Manufacturer. Price: Contact a sales representative for a quote. The PXIe-4136 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers. Please call or email us with your request. Price: Contact a sales representative for a quote. Find new, used, and rental NI PXIE-4138 PXI Source Measure Unit at Electro Rent +1 800 553 2255 Contact LA. Contact us with questions for pricing. 如果這些卡中的任何一個檢測到遠程感測端子連接不當,它將關閉輸出並進入錯誤狀態。. •Current Range: -1 A to 1 A. Revisions C and later of the PXIe-4136/7, and revisions H and later of the PXIe-4138/9 now include an additional 4 connection points for chassis ground on the main front panel connector, revealed by 4 extra holes in the front panel sticker overlay. Page 10 Sense HI Load1 Sense LO Set the first specified level range, limit range, and limit on the PXIe-4136. The PXIe‑1086 incorporates hot-swappable, redundant AC power supplies as well as hot-swappable, front-accessible, redundant cooling fans. •Current Range: -100 mA to 100 mA. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. Farnell Israel offers fast quotes, same day dispatch, fast delivery, wide. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. Hardware Services. The module supports DMA streaming between the host PC and SMU, so you can stream. The following section provides information about the PXIe-1083 AC input and DC output. Configuration: •Number of SMU Channels: 1. Distributor of NI PXIe-4136 PXI Source Measure Unit (1 Channel, DC ±200V/±1A, 1 pA) NI Call for best price. PXIe-4136 Product Certification(s) You can request repair, schedule calibration, or get technical support. The module supports DMA streaming between the host PC and SMU, so you can stream. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. •Voltage Range: -200 V to 200 V. Newark. PXIe-4136 Current/Voltage Measure, Current/Voltage Source 20W ± 200V ± 1A - 3 Years 784483-01 3620592 Data Sheet + RoHS. For information about the device specifications, refer to the NI PXIe-7976R Specifications,Buy 784068-01 - Ni - Screw Terminal Connector Kit, PXIe-4136/7/8/9 SMUs. This module uses a pair of channels to. You can use the VST to test a variety of cellular and wireless standards such as Wi-Fi 6 and 5G NR. Accessory Type:Screw Terminal Connector Kit; For Use With:NI PXIe-4136/7/8/9 SMUs; Product Range:- RoHS Compliant: YesThe output terminals of the PXIe-4136 are electrically isolated from chassis ground through a 250 V DC , Category I isolation barrier. Click here to sell your equipment! •Number of SMU Channels: 1 •Voltage Range: -60 V to 60 V •Current Range: -3 A to 3 A •Current Sesitivity: 1 pA •Source Adapt: No Part Number: 782856-01 Please contact Artisan Technology Group Sales for configuration pricing and availability. 請注意,如果機箱本身是PXI機箱而不是PXIe,則任何插槽中都無法相容任何樣式的PXIe卡。. All other SMUs will have a non-zero current which will be sinked in the SMU. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Note In this document, the PXIe-4139 (40W) and PXIe-4139 (20W) are referred to inclusively as the PXIe-4139. PXIe-4137 ensures that if measurement is accurate, then output is as well, and vice versa. ). The reference clock frequency for the PXIe 5413 PXI Waveform Generator is 100 MHz (<±25 ppm) and the sample clock rate is 800 MHz. Description. The. Figure 2. PXIe-1095 This document contains specifications for the PXIe-1095 chassis. Price does not include custom duties and taxes. Contact Us. Single-channel system source measure unit smu (16 pages) Measuring Instruments National Instruments PXIe-4163 Getting Started Manual. Measured at the end of the 1 m SHDB62M. Get a quote for a Used PXIe 4136 Miscellaneous Test Equipment from Apex Waves, LLC at used-line. To meet XI Express cooling requirements, this model features 30 Watt per slot cooling. You can configure each line for input or output and you also can configure each line with a user-configurable pull-up or pull-down resistor. Each channel has an Analog to Digital Converter. 6 T cal is the internal device temperature recorded by the PXIe-4136 at the completion of the last self-calibration. PXIe-4147 PXIe-4162 PXIe-4163 Driver. Farnell Ireland offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. National Instruments PXIe-4135 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. •Voltage Range: -200 V to 200 V. Sanitization processes for the M8920A, M9470A, M9421A, and M9260A product models are covered in this document. Fast Quotes & Shipping. Description. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. versions of the PXIe-4135 unless otherwise specified. PXIe, 20 MHz Bandwidth, 1- or 2-Channel, 16-Bit PXI Waveform Generator. Product Compliance Certificate Download Product Compliance Certificate. Product Compliance Certificate Download Product Compliance Certificate. To access NI 4136/4137 documentation, navigate to Start»All Programs»National Instruments »NI-DCPower»Documentation . The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research. This document explains how to install, configure, and test the NI PXIe-4136/4137 (NI 4136/4137). National Instruments PXIe-4136. PXIe-54x3 instrument use one or two independent,16-bit digital-to-analog converter to generate signal with excellent sine wave flatness. These specifications are typical for the range of 0 °C to 55 °C unless otherwise stated. Ideal for lab characterization, board-level testing, and manufacturing test environments, it is proficient at working with integrated circuits ( National Instruments PXIe-4136 | In Stock. General and. PXIe, 32 AI (16-Bit, 2 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module. Likewise, the connector kit that ships with these new SMU's now includes 4 additional. The module supports DMA streaming between the host PC and SMU, so you can stream large waveforms. By using the Co-Browse feature, you are agreeing to allow a support representative from DigiKey to view. For the NI PXIe-8135 specifications and details about the differences between the PXIe-8135 Windows 10 and other models, visit apexwaves. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40Buy Ni 786818-01 online at Newark Canada. secure the SA-413B onto a PXIe-4136/4137/4138/4139 using the two retaining screws to a torque of 0. The actual product may differ from image shown. 注意: pxie-414x 和 pxie-4136 / 4137/4138/4139 具有可將電流值設為 0a 優點,可以不吸收電流;這在測量高阻抗電壓源時至關重要。 所有其他 smu 不能將電流值設為 0 ,該電流將被 smu 吸收。 下表列出了 smu 設備的可設置的最小電流值。Note: The PXIe-414x and the PXIe-4136/4137/4138/4139 have the added advantage of a 0A current level allowing it to sink 0 current; this is crucial when measuring high impedance voltage sources. Delete from my manuals. 8 PXIe-4162 configured for fast transient response. Price may vary with addition of accessories and services. The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. National Instruments PXIe-4139 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. 5. Please contact Artisan Technology Group Sales for pricing and availability. Measuring Instruments National Instruments PXIe-4136 Getting Started Manual. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Configuration: • Frequency Range: 65 MHz to 6 GHz. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Price: Contact a sales representative for a quote. •Current Range: -3 A to 3 A. Table 1. PXIe-4137 measuring instruments pdf manual download. A valid service agreement may be required. 01 1 0. This PXI Ethernet Interface Module includes four RJ45 10/100/1000BASE-T. 2. PXIe-4137 PXIe, ±200 V, ±1 A (DC)/±3 A (Pulsed), 100 fA Precision System PXI. PXIe-4136 Current/Voltage Measure, Current/Voltage. 39: Manufacturers Standard Package. The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. NI PXIe-4163 Source Measure Unit (SMU) Stock # 95045-14 Add to Cart. PXIe, 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module. Could you try going through those steps and seeing if that allows you to reset the safety interlock? If going through the safety interlock test in step 5 above fails, your PXIe-4136 SMU may be damaged. The NI PXIe-6363 Multifunction I/O Module has 16-bit resolution per channel, and a maximum sample rate of 2 MS per second. 01 1 0. Farnell France offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. Note In this document, the PXIe-4466, PXIe-4467, and PXIe-4468 are referred to inclusively as the PXIe-446x. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. 2. Contact us with questions for pricing. 2770-786818-01. Source Measure Unit SMU, 24- Channel, 4-Quadrant, PXIe-4163, ± 50mA, ± 24V, 1. AC Input. PXIe, 7½-Digit, ±1,000 V, Onboard 1. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40Home Support Documentation Product Certifications PXIe-4136 Product Certifications. Contact us with questions for pricing. The glyphs underneath each slot are visually different to PXI so that there is a clear indication this is a PXIe slot, PXIe uses a dark background with white slot numbering whereas PXI uses a light background with dark slot numbering. PXIe, 80 MHz Bandwidth, 1- or 2-Channel, 16-Bit PXI Waveform Generator. Question: What is the PXIe-4137 module’s current sensitivity?. NI-DCPower Issue Details. The module supports DMA streaming between the host PC and SMU, so you can stream. Calibration procedure, single-channel system source measure unit (smu) (26 pages) Measuring Instruments NI PXIe-4141 Calibration ProcedureView and Download NI PXIe-4190 getting started online. 01 1 0. In addition, you can expand the small, two slot 2U PXI Express form factor to support multiple. 1 1 0. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital. •Current Sesitivity: 10 pA. You use it for processor-intensive, modular instrumentation, and data acquisition applications. Screw Terminal Connector Kit, PXIe-4136/7/8/9 SMUs. 修理、RMA、キャリブレーション予定、または技術サポートをリクエストいただけます。. Measuring Instruments National Instruments PXIe-4136 Getting Started Manual. PXI System Source Measure Units PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • SourceAdapt digital control loop technology • Four-quadrant source and. 06 GHz, Quad-Core, Intel Core i7-820QM Embedded Controller for PXI and CompactPCI frameworks. Part Number: 781161-02, 196695J-01L, 199042B-01L. PXIe-5450 PXIe-5611 2x PXIe-5651 PXIe-5601 + MORE! $9,774. PXIe-4136 Calibration Procedure(s) Visual Diagrams . The system must be allowed to warm up for 15 minutes to achieve the rated accuracy. The PXIe-4138 system source measure unit (SMU) delivers high. The device has a maximum system bandwidth of 3 GB/s. Configuration: •Number of SMU Channels: 4. Buy 786818-01 - Ni - Banana Jack Adapter, PXIe-4136/7/8/9 SMUs. 7 lb · in. Sign in. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40 PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. 09. Part Number: 198666E-01L, 198754B-01L, 780321-01. The PXIe-6672 and PXI-6683 modules contain a temperature-compensated crystal oscillator (TCXO) which can achieve accuracies better than 4 ppm. pin states, and system status. PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139. Related Information Reverification on. •Current Sesitivity: 100 fA. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure UnitYour productivity is our priority, that’s why we will do everything we can to make sure your National Instruments PXIe-4136 System SMU is back to you in working order as soon as possible. The device delivers high-performance functionality leveraging the high. PDF. Note: only the PXIe-414x, PXIe-4136/4137, and PXIe-4138/9 will allow you to set the current level to 0; all other NI SMUs have a minimum current level, typically 2% of the current range. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. com | PXIe-4136 Specifications Maximum measure rate to host 1. 8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter. This allows any SMU terminal to float ±250 V DC with respect to chassis ground. 0 ports, four USB 2. PXIe-4139, PXIe-4141) 05-10-2022 06:36 PM. Solution. Contact us with questions for pricing. Complies with the essential requirements of the following applicable European Directives: Electromagnetic Compatibility (EMC) Directive 2014/30/EU Low-Voltage (Safety) Directive 2014/35/EU技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe, ±200 V, ±1 A (DC)/±3 A (Pulsed), 100 fA Precision System PXI Source Measure Unit. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40Price may vary with addition of accessories and services. 95. The PXIe‑8430/16 is a high-performance interface for high-speed communication with RS232 devices. Sign In Upload. 96. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit. com. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. pdf ⭳ Download pdf. 5 GHz. Solution. 8 MS/s Isolated Digitizer, PXI Digital Multimeter The PXIe‑4081 is the industry’s most accurate 7½‑digit DMM and provides the measurement capabilities found in two common test instruments: a high-resolution 1,000 V DMM and a digitizer. •Voltage Range: -200 V to 200 V. PXIe-4190 measuring instruments pdf manual download.